中国塑料 ›› 2018, Vol. 32 ›› Issue (05): 92-96.DOI: 10.19491/j.issn.1001-9278.2018.05.014

• 加工与应用 • 上一篇    下一篇

核电站高密度交联聚乙烯高完整性容器抗跌落和贯穿的安全评估

刘峰,刘夏杰,吕永红   

  1. 中广核研究院有限公司
  • 收稿日期:2017-11-07 修回日期:2018-01-29 出版日期:2018-05-26 发布日期:2018-05-25

Security Assessment for Anti-falling and Anti-penetrating Performance of Cross-linked High-density Polyethylene High Integrity Container for Nuclear Power Station

  • Received:2017-11-07 Revised:2018-01-29 Online:2018-05-26 Published:2018-05-25

摘要: 利用非线性动力分析软件LS-DYNA仿真分析了高密度交联聚乙烯完整性容器(PE-XHD-HIC)在核电产业使用过程中的跌落和贯穿2种典型工况,论证了国产化高完整性容器(HIC)的安全性能。仿真结果显示,高完整性容器在1.2 m的跌落过程和贯穿过程两种典型工况下,容器的最大应力均小于材料强度极限,最大应变小于材料的破坏应变;国产化PE-XHD-HIC满足在跌落和贯穿事故下的性能要求,使用安全可靠。

Abstract: The cross-linked high-density polyethylene high integrity container (PE-XHD-HIC) has been applied to deal with low-and middle-radioactive wastes of nuclear power station. A security assessment for PE-XHD-HIC was performed by the nonlinear dynamics software LS-DYNA to simulate its anti-falling and anti-penetrating performance at a height of 1.2 m under the two typical actual accident conditions of nuclear power station. The simulation results indicated that the stress of PE-XHD-HIC was less than its ultimate strength, whereas its maximum strain was less than the damage strain. The PE-XHD-HIC was verified to meet all the requirements in operation and security.